Original Article Short Insulin Tolerance Test(SITT) for the Determination of in vivo Insulin Sensitivity-A Comparison with Euglycemic Clamp Test.
Seok Won Park, Yong Seok Yun, Churl Woo Ahn, Jae Hyun Nam, Suk Ho Kwon, Min Kyung Song, Seol Hye Han, Bong Soo Cha, Young Duk Son, Hyun Chul Lee, Kap Bum Huh
Diabetes & Metabolism Journal 1998;22(2):199-208
DOI: https://doi.org/
Published online: January 1, 2001
  • 1,291 Views
  • 35 Download
  • 0 Crossref
  • 0 Scopus

BACKGROUND
The euglycemic hyperinsulinemic clamp technique is currently regarded as gold standard for measuring insulin sensitivity, but it requires sophisticated equipment and highly trained personnel. We investigated the reliability of short insulin tolerance test as a simple tesl to measure in vivo insulin sensitivity. METHODS: Short insulin tolerance test(SITT) and euglyeemic hyperinsulinemic clamp test were performed at random order in 14 healthy subjects and 10 abnormal glucose tolerant subjects. The plasma glucose disappearance rate(kitt: %/min) after iv injection of regular insulin(0.1U/kg) was determinecl and compared to insulin sensitivitv indices(M, M/I) of euglycemic hyperinsulinemic clamp test. RESULTS: The mean Kitt value of healthy subjects was 3.50+0.75%/min and that of subjects with abnormal glucose tolerance was 2.56+0.56%/min. Changing sampling time from 15 min to 18~21 min and sampling interval from 3 min to 1.5 min had no influence on Kitt value. Kitt values were reproducible in six subjects, with a CV of 8.8+2.0%. There was a highly significant correlations between the Kitt value derived from SITT and M or M/I derived from euglycemic hyperinsulinemic clamp test. There were no significant adverse effects including hypoglycemic symptom while performing SITT. CONCLUSION: SITT is simple, safe, rapid to perform, and provides reliable index of in vivo insulin sensitivity. It seems particularly suitable for studies involving large series of subjects or including repeated evaluation of insulin sensitivity.

  • Cite
    CITE
    export Copy
    Close
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Short Insulin Tolerance Test(SITT) for the Determination of in vivo Insulin Sensitivity-A Comparison with Euglycemic Clamp Test.
    Korean Diabetes J. 1998;22(2):199-208.   Published online January 1, 2001
    Close
Related articles

Diabetes Metab J : Diabetes & Metabolism Journal